This series of blower impeller adopts the international leading three-way flow design technology for aerodynamic design, reliable performance, efficiency than the traditional two-way flow design fan increased by 8~12%. The blade and hub of the impeller are forged as a whole and are milled by a five-coordinate CNC milling machine. The semi-open structure is adopted to ensure that the impeller has sufficient strength and safe operation. The impeller is made of high-strength forged aluminum alloy 7A09 or FV520B and other high-strength alloy steel with high strength, light weight and good anti-corrosion performance (according to the contract). After machining the impeller, the overrunning test was carried out.
Advanced aerodynamic design and efficient motor systems provide stable and efficient air flow in various production processes. By optimizing airflow distribution and reducing energy loss, the Shuangjian blower can significantly improve energy efficiency.
Shuangjian blower adopts strict standards and measures in quality control. From raw materials into the factory to finished products, every link has undergone strict quality testing and monitoring. Through advanced testing equipment.
High quality accessory selection and reliability design provide sufficient equipment strength and durability for the Shuangjian blower, and reduce maintenance costs. Selection of domestic and foreign well-known brand accessories.
The fan is equipped with sliding bearing, thin oil station, high fuel tank and a complete set of safety interlock protection system, and the shell is horizontally divided, and the fan inlet and outlet pipes are horizontally connected with the shell inlet.
Hubei Shuangjian has dozens of CNC machine tool production lines and robot welding equipment, from steel plate cutting, bending, planing, milling to painting, all realize digital control, high processing precision, some core components accurate.
Hubei Shuangjian as a set of production and sales in one of the strength of the enterprise, we are responsible for their production of each piece of equipment, to provide customers.
This series of blower impeller adopts the international leading three-way flow design technology for aerodynamic design, reliable performance, efficiency than the traditional two-way flow design fan increased by 8~12%. The blade and hub of the impeller are forged as a whole and are milled by a five-coordinate CNC milling machine. The semi-open structure is adopted to ensure that the impeller has sufficient strength and safe operation. The impeller is made of high-strength forged aluminum alloy 7A09 or FV520B and other high-strength alloy steel with high strength, light weight and good anti-corrosion performance (according to the contract). After machining the impeller, the overrunning test was carried out.
Fan structure is simple, with a first gear growth. The impeller is installed on the high-speed gear shaft of the speed increasing machine, and the static and dynamic balance test is carried out after assembly to ensure the balanced and reliable operation of the fan. The main fan, turbocharger, main motor and electric pump, oil cooler, oil filter and other auxiliary machines are installed on a common base, the base is also a fuel tank, so the structure is simple, easy to lift and occupy a small area.
The support and thrust bearings of the fan speeder are made of plain bearings with forced oil supply, and the fan is made of diaphragm coupling.
This series of blower is mainly used for sewage treatment aeration blast, can also be used for other occasions according to the performance of the air or non-toxic, non-corrosive gas.
Flow range: 60-1200m²/min
Outlet pressure boost:: 0.25mpa
Sewage treatment centrifugal blower performance table
Model
|
Medium
|
Inlet condition
|
Outlet pressure boost mmH2O
|
Shaft powerKW
|
Matching motor
|
||||||
Flow m/miln
|
Temperature ℃
|
Density Kg/m3
|
Pressure Kgf/cm2
|
Model
|
Power KW
|
|
Voltage V
|
C20—1.5
|
air
|
20
|
20
|
1.16
|
1
|
5000
|
21.7
|
Y225M-2
|
45
|
380
|
|
|
|||||||||
C40—1.5
|
air
|
40
|
20
|
1.16
|
1
|
5000
|
43.5
|
Y250M-2
|
55
|
380
|
1.16
|
1
|
|
|
|||||||
C60一1.5
|
air
|
60
|
20
|
5000
|
65.3
|
Y280S-2
|
75
|
380
|
||
C80—1.5
|
air
|
80
|
20
|
1.16
|
l
|
5200
|
87.1
|
|
|
|
Y280M-2
|
90
|
380
|
||||||||
C100—1.5
|
air
|
100
|
20
|
1.16
|
1
|
5000
|
108.9
|
|
132
|
380
|
C125—1.5
|
air
|
125
|
20
|
1.16
|
1
|
5000
|
136.1
|
Y315M-2
|
160
|
|
|
380
|
|||||||||
C125—1.65
|
air
|
125
|
20
|
1.16
|
1
|
6500
|
228.7
|
Y315L-2
|
200
|
380
|
C150—1.5
|
air
|
150
|
20
|
1.16
|
l
|
5000
|
196
|
|
|
380
|
Y315M-2
|
200
|
|||||||||
C150—1.7
|
air
|
150
|
20
|
1.16
|
1
|
7000
|
274.5
|
|
250
|
|
Y315M4-2
|
380
|
|||||||||
C180—1.5
|
air
|
180
|
20
|
1.16
|
1
|
5000
|
217.7
|
Y315M3-2
|
220
|
380
|
C180—1.7
|
air
|
180
|
20
|
1.16
|
1
|
7000
|
305
|
JK132—2
|
290
|
380
|
C200—1.5
|
air
|
200
|
20
|
1.16
|
1
|
5000
|
272.3
|
Y135M4-2
|
250
|
380
|
C200—1.7
|
air
|
200
|
20
|
1.16
|
1
|
7000
|
381.2
|
JK134—2
|
360
|
380
|
C250—1.5
|
air
|
250
|
20
|
1.16
|
1
|
5000
|
326.7
|
JK132-2
|
290
|
380
|
C250—1.7
|
air
|
250
|
20
|
1.16
|
l
|
7000
|
457.5
|
JK135-2
|
440
|
6000
|
C300—1.5
|
air
|
300
|
20
|
1.16
|
1
|
5000
|
381.2
|
JK134-2
|
360
|
380
|
C300—1.7
|
air
|
300
|
20
|
1.2
|
l
|
7000
|
533.7
|
JK500-2
|
500
|
6000
|
C350—1.5
|
air
|
350
|
20
|
1.16
|
l
|
5000
|
435.7
|
JK135-2
|
440
|
6000
|
C350—1.7
|
air
|
350
|
20
|
1.16
|
l
|
7000
|
533.7
|
JK630-2
|
630
|
6000
|
C400—1.5
|
air
|
400
|
20
|
1.16
|
1
|
5000
|
435.7
|
JK500-2
|
500
|
6000
|
C400—1.7
|
air
|
400
|
20
|
1.16
|
l
|
7000
|
161
|
JK800-2
|
800
|
6000
|
C450—2.15
|
air
|
450
|
20
|
1.16
|
1
|
11500
|
951.4
|
YKl000—2/990
|
1000
|
6000
|
Appearance inspection: Check the appearance of the blower regularly to confirm that there is no damage, deformation or rust.
Running sound: Monitor the running sound of the blower. If there is abnormal sound, stop the machine immediately for inspection.
Vibration: Check the vibration of the blower regularly to ensure that it is within the allowed vibration range.
Lubricating oil inspection: check the oil level and quality of lubricating oil regularly to ensure that it is within the specified range, and replace the deteriorated lubricating oil in time.
Grease replacement: For the parts that use grease, it is necessary to replace it regularly to ensure the lubrication effect.
Cooling water inspection: For the blower with water cooling, it is necessary to regularly check the flow rate and temperature of the cooling water to ensure that the cooling effect is good.
Cooler cleaning: Clean the cooler regularly to prevent its blockage affecting the heat dissipation effect.
Internal cleaning: Regularly clean the dust and debris inside the blower to avoid damage to the blower.
Fastener inspection: Check the fasteners inside the blower to ensure that they are tight and not loose.
Motor inspection: Check the running status of the motor regularly to ensure its normal operation.
Cable check: Check the connection and insulation of the cable to ensure that there is no damage or aging.
Shutdown cleaning: When the blower is shut down, thoroughly clean the dust and dirt inside and outside the blower.
Downtime inspection: Use downtime to conduct a thorough inspection of the blower to find and deal with potential problems.
Our company has strong technical research and development capabilities, and has established several research workstations to bring sustained vitality to the improvement and progress of Shuangjian's technical research and development capabilities.
Supporting auxiliary support technology and functional control technology for modern design and manufacturing of new wind turbines, establishing a network CAD system, using deformable simulation analysis software to achieve intelligent product design and process design.
Our company has developed dozens of quality management documents in accordance with the requirements of the ISO9001:2000 quality management system, including the Quality Manual, Procedure Documents, Incoming Inspection Specification, Process Inspection Specification, Finished Product Inspection Specification, Equipment Operation Regulations, Assembly Operation Manual, and Test Equipment Operation Manual.
We are willing to continue to cooperate sincerely with new and old friends at home and abroad with higher quality products and more comprehensive services, and create win-win results together as always!
Sales Hotline:
Mobile version
WeChat official account
Add:Guangshui Economic Development Zone, Hubei Province
Tel:+86-722-6430098 +86-722-6430068
Tel:+86-18108610199
Email:sjxs@hbfj.cn
Copyright(C)2024,Hubei Shuangjian Blower Production Co., Ltd. Supported by ChemNet ChinaChemNet Toocle 31fabu Copyright Notice